Instrument

The instrument configuration can be a great starting point for analysis. This configuration includes information such as the beam energy, beam vector, and the number, type, and positions of detectors. There are a variety of ways to configure the instrument. A brief summary is provided below.

Loading and Saving

The simplest way to configure an instrument is to load a pre-existing configuration. These configurations are contained in either yaml files or HEXRD (an HDF5 file with a .hexrd extension) files. Loading a state file will also set the instrument configuration (see state files).

To load an instrument configuration, click File->Open->Configuration, and then select an instrument configuration file. A few examples can be found here:

When you are satisfied with your instrument configuration, you may save it to a file via File->Save->Configuration. You can then select either a yaml or HEXRD file format. The yaml format has the benefit of being easier to read, but the HEXRD format is necessary for configurations that include, for instance, 2D panel buffers.

There are several ways to manually configure an instrument. Those methods will be covered below.

Tree View

Tree View

The tree view provides a yaml-like view of your instrument configuration. It can be helpful especially if you are familiar with using the HEXRD yaml files.

In this view, you are able to see and edit most of the values in the instrument configuration. Any edits should cause a live update in the image canvas (as long as View->Show Live Updates is checked). You are also able to edit which parameters are refinable here, which is helpful if you plan to run a calibration later (see refinements for more details about calibration refinements).

There are some context menu options available if you right-click a row in the tree view. For instance, you may collapse/show a row and all of its children, or check/uncheck the refinable option for a row and all of its children.

Form View

Form View

The form view uses widgets to display the instrument configuration, and it offers some additional methods for configuring the instrument.

For instance, if the x-ray was produced by burning a metal foil, it may be selected through the "Select Energy from X-Ray Table" button. The beam vector can be specified by either polar or cartesian coordinates. Whether or not there is a finite source distance (used primarily for pinhole distortion methods) may be specified. A distortion function may be applied (such as GE_41RT). And detectors can be added (with the + button), removed (with the - button), or renamed (using the combo box in the "Detector Parameters" section).

In the form view, a gray background for the widgets indicates that they are not refinable (see the refinements section) during calibration.

X-Ray Energy Selection

X-Ray Energy Selection

In the form view, if the "Select Energy from X-Ray Table" button is clicked, the above dialog should appear.

If the x-ray was produced by burning a metal foil, the x-ray energy may be selected through this dialog.

The displayed table provides absorption edges and emission lines for a variety of elements. A single row can be selected to use the energy of that entry, or multiple rows can be selected, in which case, their energies will be averaged together.

Panel Buffers

Panel Buffer

If Configure Panel Buffer is clicked, then the panel buffer options for the currently selected detector will appear. The panel buffer is used to exclude some pixels in the images from the view modes and various analysis methods.

The Border mode of the panel buffer indicates that pixels along the borders should be excluded. The input is in mm, and the number of pixels excluded is computed automatically from this.

Alternatively, a NumPy array (.npy file) may be provided. This is a 2D boolean array that matches the shape of the detector exactly, and it explicitly indicates which pixels should be kept/ignored. This array can be viewed by clicking Show Panel Buffer.

Epix Quad Panel Buffer

Purple pixels are excluded, and yellow pixels are included.

The panel buffer may also be cleared entirely by clicking Clear Panel Buffer.

Slider View

Slider View

The slider view provides interactive sliders for editing detector and beam parameters. For editing detector parameters, the detector must be specified in the combo box at the top.

The "Slider Range" for each section indicates what the range of the slider will be. Note that modifying the slider range will also reset the slider to the center of the range (which is necessary to go beyond the original ranges).

One use case for the slider view is to roughly set the detector parameters manually ("eyeball" it), so that any automatic calibration afterwards is more likely to succeed. For instance, if one detector is translated incorrectly, as shown below:

Slider View Before Adjustment

The sliders can be used to interactively move the detector to roughly the correct position:

Slider View After Adjustment

This can help ensure that calibration will succeed.

The Reset Configuration button at the bottom may be used to reset the configuration (see here for more details).

Note: increase the Cartesian pixel size (e.g., to 1) for faster interactivity

Additional Details

Euler Angle Convention

Since the detectors are in 3D space, their tilt angles can be displayed and specified using a variety of conventions. By default, HEXRDGUI uses the Extrinsic XYZ Euler angle convention. This is modifiable, however, under Edit->Euler Angle Convention.

Currently, the other options are None (which uses the exponential map parameters), and Intrinsic ZXZ.

The tree view, form view, and slider view will all display their detector tilt angles using the selected Euler angle convention.

Resetting the Instrument Configuration

When the instrument configuration is first loaded, it is saved internally, so that it may be restored at any time by clicking the Reset Configuration button. This feature is available in both the slider view, and via Edit->Reset Instrument Config.

Detectors with subpanels

ROI Dexelas Cartesian View

When a detector contains subpanels (e.g., Dexela, Pilatus, Eiger), the subpanels are not always perfectly aligned with one another. This misalignment can introduce greater inaccuracies when performing analysis on the data.

Treating the subpanels as separate detectors, where each subpanel has its own tilt/translation (thus allowing each subpanel to take into account any misalignment), has been shown to improve the quality of calibration and accuracy of subsequent analysis. HEXRDGUI provides a special way to do this (see here for the example used in this section).

First, an instrument config needs to be created that contains a separate detector entry for each subpanel. For example, see here two subpanels (ff1_0_0 and ff1_0_1) out of the four subpanels for a single Dexela panel (ff1):

detectors:
  ff1_0_0:
    pixels:
      rows: 1944
      columns: 1536
      size: [0.0748, 0.0748]
      roi: [0, 0]
    group: ff1
    saturation_level: 15000
    transform:
      tilt: [0, 0, 0]
      translation: [66, 76, -670]
  ff1_0_1:
    pixels:
      rows: 1944
      columns: 1536
      size: [0.0748, 0.0748]
      roi: [0, 1536]
    group: ff1
    saturation_level: 15000
    transform:
      tilt: [0, 0, 0]
      translation: [181, 76, -670]

If the image data is already split up into separate subpanels, each subpanel can just be treated as a separate detector with no other special considerations (analysis can be performed as usual). However, the image data most likely contains the data from each subpanel stitched together. In this case, we need to define regions in the image data for each subpanel.

In the configuration, each subpanel entry should contain an roi (region-of-interest) entry under pixels, which indicates the start in pixel (ij) coordinates for that subpanel within the larger panel image. The rows and columns should be equal to the size of the subpanel (not the whole panel). These are used to determine how many pixels to read past the start roi values. Dexela detectors are 3888x3072, and contain 4 subpanels, where each subpanel is 1944x1536. For Dexela detectors, the ROIs for subpanels ff1_0_0, ff1_0_1, ff1_1_0, and ff1_1_1 are [0, 0], [0, 1536], [1944, 0], and [1944, 1536], respectively.

Once the roi is set up properly, a group key must be present as well, which indicates which panel each subpanel belongs to. For Dexela detectors, this usually means ff1_0_0, ff1_0_1, ff1_1_0, and ff1_1_1 are all in group ff1. The group key can be anything, as long as all subpanels within the same panel contain the same group key.

When the roi and group keys are present for each detector, the Simple Image Series Loader may be used to load in the two larger panel images. The software will automatically detect that it is set up for subpanels, and allow the user to load in the larger panel images (rather than a smaller image for each subpanel).

ROI Simple Image Series Load

The files may be loaded with or without aggregation (depending on the Simple Image Series settings).

After loading, a few special options for this subpanel setup are present within HEXRDGUI. With the raw view active, a checkbox appears in the raw view options titled "Stitch ROI Images". If checked, the images will be stitched together, with their group label at the top.

ROI Stitching

After the subpanels have been stitched together, the mouse hover information at the bottom of the window also displays the current subpanel that the mouse is hovering over.

The other raw view settings (including Tabbed View, Show Saturation, and Show Zoom Dialog) all automatically take into account this stitched setting. This is helpful for visualizing the data from the whole panels (as loaded). However, all calculations (including the simulated overlays displayed on the raw view) still treat each subpanel as a separate detector.

Another special option appears in the slider view labeled "Lock ROI Group Transformations". If checked, translating/rotating one subpanel via a slider will translate/rotate all other subpanels in the same group by the same amount (for rotation, the subpanels will be rotated about the center of the subpanels).

Note: increase the Cartesian pixel size (e.g., to 1) for faster interactivity

ROI Lock Transforms Sliders

The HEDM workflow can be performed as usual, where each subpanel will be treated as a separate detector.

In the near future, we plan to allow for additional constraints to be placed between subpanels when performing instrument calibration, so that the relative translations/tilts between subpanels may be fixed.